F2HG14
MODELS SHOWN:
9121-AM2-M
9121-AM2-T
Technical Data
Item
Units
9120-F2HG14A-M
9120-F2HG14A-T
ID
-
-
Suitable on
Quick-Change Master
Quick-Change Tool
Module Mounting Pattern
J
J
Transmission Type
Liquids
Liquids
0.61
Weight
kg
0.71
Min./Max. Ambient Temperature
°C
5/60
5/60
Connection Outlet
Axial
Axial
Feed-Throughs
2x G1/4
2x G1/4
Medium Type
Hydraulic, water
Hydraulic, water
Volumetric Flow Per Feed-Through
l/min
6.6
6.6
Max Operating Pressure
bar
160
160
The pressure may only be applied to one port at any
time. The high pressure creates separation forces,
which greatly reduces the additional loads the tool
changer can support. The ports are self-sealing.
A small amount of liquid residue may remain on
the surface of the ports when they are uncoupled.
The amount of liquid depends on the type of fluid
processed.
The pressure may only be applied to one port at any
time. The high pressure creates separation forces,
which greatly reduces the additional loads the tool
changer can support. The ports are self-sealing.
A small amount of liquid residue may remain on
the surface of the ports when they are uncoupled.
The amount of liquid depends on the type of fluid
processed.
Special Properties